When the space is very confined and two simultaneous detections are required.
Environment whose temperature is higher than the standard holding.
For example, two phonic wheels too close to each other for two sensors to fit.
Another example: on alternators or starter-alternators in freewheel + main mode or crankshaft pulley and damper vision.
Recommendations:
- Consider mounts that clamp the ends and dampen any vibrations
- Above 1 meter in length, over-sheathing is required (Ref. SURG)
- The SPIRAL option allows you to orientate the probe without constraint
These probes have special protections for increased temperature exposure compared to standard models.
Glass fibre-biundle probes
Proximity operation with dual opposed and antagonistic detections.
Robust M10x85 stainless steel cylindrical probe with dual flat and opposing optical outputs 7.5mm thick on field.
Requires two 152 sensors.
Under specification the two half moons can be orientated to fine tune the resolution to suit the customer's installation depending on the axes of rotation